Direct reading remote transmission cold water meter
The direct reading remote transmission cold water meter is a measuring instrument used to measure the total volume of water flowing through the tap water pipeline, suitable for small industrial and household water use.
The dry structure counting mechanism is vacuum sealed, and the dial wheel is not affected by water quality, resulting in permanently clear readings; The character wheel displays a large range and high accuracy of the count value.
Technical Specifications
| モデル | Nominal caliber | Common traffic | Q3/Q1 | Overload traffic | Common traffic | Threshold flow | Minimum flow | Accuracy |
| Q3 | Q4 | Q3 | Q2 | Q1 | Grade | |||
| mm | m3/h | m3/h | L/h | |||||
| LXSY-15EZ | 15 | 2.5 | 160 | 3.125 | 2.5 | 25 | 15.6 | Level 2 |
| 125 | 32 | 20 | ||||||
| 100 | 40 | 25 | ||||||
| 80 | 50 | 31.3 | ||||||
| 63 | 63.5 | 39.7 | ||||||
| LXSY-20EZ | 20 | 4 | 160 | 5 | 4 | 40 | 25 | |
| 125 | 51.2 | 32 | ||||||
| 100 | 64 | 40 | ||||||
| 80 | 80 | 50 | ||||||
| 63 | 101.6 | 63.5 | ||||||
| LXSY-25EZ | 25 | 6.3 | 80 | 7.875 | 6.3 | 126 | 78.8 | |
| 63 | 160 | 100 | ||||||
| 50 | 201.6 | 126 | ||||||
| LXSY-32EZ | 32 | 10 | 80 | 12.5 | 10 | 200 | 125 | |
| 63 | 254 | 158.7 | ||||||
| 50 | 320 | 200 | ||||||
| LXSY-40EZ | 40 | 16 | 80 | 20 | 16 | 320 | 200 | |
| 63 | 406.3 | 254 | ||||||
| 50 | 512 | 320 | ||||||
| LXSY-50EZ | 50 | 25 | 80 | 31.25 | 25 | 500 | 312.5 | |
| 63 | 634.9 | 396.8 | ||||||
| 50 | 800 | 500 | ||||||
Maximum allowable error:
a) The maximum allowable error for the low zone (Q1 ≤ Q<Q2) is 5%;
b) The maximum allowable error for the high zone (Q2 ≤ Q ≤ Q4) is ± 2%.

| モデル | 口径 | L | B | H | Connection method | Weight | Connecting wire | |
| mm | d | D | kg | |||||
| LXSY-15EZ | 15 | 165 | 95 | 120 | R1/2 | G3/4B | 1.4 | 1.2 |
| LXSY-20EZ | 20 | 195 | 95 | 120 | R3/4 | G1B | 1.7 | 1.2 |
| LXSY-25EZ | 25 | 225 | 97 | 130 | R1 | G1 1/4B | 2.5 | 1.2 |
| LXSY-32EZ | 32 | 230 | 104 | 137 | R1 1/4 | G1 1/2B | 2.7 | 1.2 |
| LXSY-40EZ | 40 | 245 | 124 | 170 | R1 1/2 | G2B | 4.5 | 1.2 |
| LXSY-50EZ | 50 | 280 | 125 | 170 | R2 | G2 1/2B | 6.8 | 1.2 |
| 280 | 125 | 190 | Flange connection according to GB/T 17241.6-2008/XG1-2011 D=φ165 D1=φ125 |
11 | ||||
Note: The external dimensions, weight, and length of connecting wires are for reference only, and the actual product shall prevail.
| Temperature Grade | T30 | Sensitivity level of upstream and downstream flow fields | U0D0 |
| Maximum allowable pressure | 1.0MPa | Environmental Level | Grade B |
| Pressure loss level | △p63 | Electromagnetic environment level | Grade E1 |