09c2c9b7-7f89-454b-9f08-1dd3cbb2867a
09c2c9b7-7f89-454b-9f08-1dd3cbb2867a

1차 및 2차 통합 링 메쉬 박스

XGW-12
The XGW-12 primary and secondary fusion ring net cage is a sealed stainless steel box or GRC box that installs and debugs 12kV switchgear, transformers, DTUs, and instruments, thereby achieving the integration and modular assembly of primary and secondary systems in urban distribution networks, shortening the construction period, and greatly improving the reliability of urban power grid operation.

  • Product Advantages
    Compact in structure, compact and beautiful in appearance, the shape and color can be freely selected, and it is easy to integrate with the environment.
    Adopting prefabricated electrically touchable silicone rubber cable heads, fully sealed, fully insulated, maintenance free, and reliable to ensure personal safety.
    Realize regional power outage maintenance and reduce the scope of power outages without affecting the operation of the main network.
    The power supply method is flexible and can be used for both ring network distribution and terminal power supply.
    The box is treated with GRC or stainless steel special spray coating, which can be widely used in various harsh environments and has a long service life.
  • Application Scenarios
    This product is suitable for power supply and distribution systems with a rated frequency of 50Hz. It has the functions of connecting, transferring, and distributing electrical energy, with flexible combinations and complete functions; Widely used in urban industrial parks, residential areas, commercial centers, densely populated urban areas, railways, highways, petroleum, chemical and other places.
  • Technical Specifications
Parameter name Unit Parameter value
Rated Voltage kV 12
rated frequency Hz 50
Rated insulation level – power frequency withstand voltage to ground and phase to phase kV 42
Rated insulation level – power frequency withstand voltage fracture kV 48
Rated insulation level – lightning impulse withstand voltage (peak) to ground and phase to phase kV 75
Rated insulation level – lightning impulse withstand voltage (peak) fracture kV 85
Rated current A 630
Rated short-circuit breaking current KA 20/25
Protection level IP43

정보 양식 제출 후 더 많은 혜택 받기

*당사는 사용자의 기밀을 존중하며 모든 정보는 보호됩니다.

지금 바로 문의하고 오늘 답장을 받으세요.

저는 후아샹의 영업팀장 레오입니다. 저와 저희 팀은 기꺼이 고객님을 만나 비즈니스, 요구 사항 및 기대에 대해 자세히 알아보고 싶습니다.

Carson
Paul
Linsey

문의하기

정보 양식 제출 후 더 많은 혜택 받기

*당사는 사용자의 기밀을 존중하며 모든 정보는 보호됩니다.

지금 바로 문의하고 오늘 답장을 받으세요.

저는 후아샹의 영업팀장 레오입니다. 저와 저희 팀은 기꺼이 고객님을 만나 비즈니스, 요구 사항 및 기대에 대해 자세히 알아보고 싶습니다.

Carson
Paul
Linsey