a60244dd536965a046c1eb2c437fa090
a60244dd536965a046c1eb2c437fa090

Contador de água fria de transmissão remota com vedação por rotor

Rotor liquid seal remote transmission cold water meter
The LXSY-15F-32F rotor liquid seal remote transmission cold water meter is a water metering instrument that uses the rotor liquid seal water meter as the base meter, achieves electromechanical conversion through non-magnetic sensing technology, and uses wired communication technology for data remote transmission to centrally manage the water meter.
1. The messaging module and base table adopt a separate structure; The power supply battery is independently packaged for easy battery replacement;
2. Adopting the current mainstream M-Bus transmission technology, it has high anti-interference ability and stable and reliable signal;
3. The DN15 to DN20 signaling positions use 1L measurement, while the DN25 to DN32 signaling positions use 10L measurement, with high measurement accuracy;
4. The base table adopts an independent trust pointer, which does not affect any readings;
5. A new non-magnetic acquisition method and special precision algorithm are used to ensure the accuracy of demagnetization and counting for the counting problems often caused by water flow backflow, shaking, and magnetic interference during the use of the water meter.

Technical Specifications

  • Flow parameters
Modelo calibre Q3 /Q1 Overload trafficQ4 Common trafficQ3 Threshold flowQ2 Minimum flowQ1 Minimum reading Maximum Reading
mm m3/h L/h m3
LXSY-15F 15 80 3.125 2.5 50 31.3 0.00005 99999
100 40 25
125 32 20
160 25 15.6
LXSY-20F 20 80 5 4 80 50
100 64 40
125 51.2 32
160 40 25
LXSY-25F 25 80 7.875 6.3 126 78.8
100 100.8 63
125 80.6 50.4
160 63 39.4
LXSY-32F 32 80 12.5 10 200 125
100 160 100
125 128 80
160 100 62.5

Maximum allowable error:
a) The maximum allowable error for the low region (Q1 ≤ Q < Q2) is (5%; b) and the maximum allowable error for the high region (Q2 ≤ Q ≤ Q4) is (2% (T30) or (3% (T50)).

  • Overall Dimensions

 

 

 

 

 

Modelo calibre L H1 H2 W1 W2 Threaded connection
mm d D
LXSY-15F 15 165 35.5 102.5 47 47 R1/2 G3/4B
LXSY-20F 20 195 37 102.5 47 47 R3/4 G1B
LXSY-25F 25 225 41.5 104.5 50 50 R1 G1 1/4B
LXSY-32F 32 230 42 104.5 50 50 R1 1/4 G1 1/2B

Note: The external dimensions are for reference only, and the actual product shall prevail.

  • Performance Parameters
Data collection method Non-magnetic sensing Maximum allowable pressure 1.6MPa
Working Voltage 3.6V Protection level IP68
Electromagnetic environment level E2 level Flow field sensitivity level U0D0
Standby current (power consumption) 12±1uA Baud rate 2400bps
transmission distance 1000m (typical) modulation scheme M-Bus
Temperature Grade T30/T50 Environmental Level Grade O

Obter mais benefícios desde Enviar o formulário de informação

*Respeitamos a sua confidencialidade e todas as informações são protegidas.

Contacte-nos agora mesmo, obtenha resposta hoje.

Sou o Leo, o chefe da equipa de vendas da Huaxiang. Eu e a minha equipa teremos todo o prazer em conhecê-lo e saber tudo sobre o seu negócio, requisitos e expectativas.

Carson
Paulo
Linsey

Contactar-nos

Obter mais benefícios desde Enviar o formulário de informação

*Respeitamos a sua confidencialidade e todas as informações são protegidas.

Contacte-nos agora mesmo, obtenha resposta hoje.

Sou o Leo, o chefe da equipa de vendas da Huaxiang. Eu e a minha equipa teremos todo o prazer em conhecê-lo e saber tudo sobre o seu negócio, requisitos e expectativas.

Carson
Paulo
Linsey