Contador de água remoto sem fios para medição em ambiente húmido
The LXSY-15FW~50FW series wireless remote transmission cold water meter is a water metering instrument that uses the rotor liquid sealed cold water meter as the base meter, collects data through non-magnetic or magnetic resistance sensing methods, and transmits data remotely through wireless communication technology to centrally manage the water meter.
The messaging module and the base meter adopt a separate structure, and the power supply battery is independently packaged for easy battery replacement; Adopting current mainstream data transmission technology and advanced network topology structure, the signal is stable and reliable; DN15-20 can be measured with 1L/P or 10L/P according to demand, while DN25-50 can be measured with 10L/P or 100L/P according to demand. The measurement accuracy is high and can meet different needs; The base table adopts independent signaling pointers, which do not affect any readings.
Technical Specifications
| Modelo | Nominal diameter | Q3 /Q1 | Overload traffic Q4 | Common traffic Q3 | Threshold flow Q2 |
Minimum flowQ1 | Minimum reading | Maximum Reading |
| mm | m3/h | L/h | m3 | |||||
| LXSY-15FW | 15 | 100 | 3.125 | 2.5 | 40 | 25 | 0.00005 | 99999 |
| 125 | 32 | 20 | ||||||
| 160 | 25 | 15.6 | ||||||
| LXSY-20FW | 20 | 100 | 5 | 4 | 64 | 40 | ||
| 125 | 51.2 | 32 | ||||||
| 160 | 40 | 25 | ||||||
| LXSY-25FW | 25 | 100 | 7.875 | 6.3 | 100.8 | 63 | ||
| 125 | 80.6 | 50.4 | ||||||
| 160 | 63 | 39.4 | ||||||
| LXSY-32FW | 32 | 100 | 12.5 | 10 | 160 | 100 | ||
| 125 | 128 | 80 | ||||||
| 160 | 100 | 62.5 | ||||||
| LXSY-40FW | 40 | 100 | 20 | 16 | 256 | 160 | 0.00005 | 999999 |
| 125 | 204.8 | 128 | ||||||
| 160 | 160 | 100 | ||||||
| LXSY-50FW | 50 | 100 | 31.25 | 25 | 400 | 250 | ||
| 125 | 320 | 200 | ||||||
| 160 | 250 | 156.3 | ||||||
Maximum allowable error:
a) The maximum allowable error for the low zone (Q1 ≤ Q < Q2) is ± 5%;
b) The maximum allowable error for the high zone (Q2 ≤ Q ≤ Q4) is ± 2%.

| Modelo | calibre | L | B | H | Threaded connection | peso | |
| mm | d | D | kg | ||||
| LXSY-15FW | 15 | 165 | 92.5 | 140 | R1/2 | G3/4B | 1.5/0.8 |
| LXSY-20FW | 20 | 195 | 92.5 | 142 | R3/4 | G1B | 1.8/0.9 |
| LXSY-25FW | 25 | 225 | 99 | 148 | R1 | G1 1/4B | 2.2 |
| LXSY-32FW | 32 | 230 | 99 | 148.5 | R1 1/4 | G1 1/2B | 2.5 |
| LXSY-40FW | 40 | 245 | 116 | 185 | R1 1/2 | G2B | 4.5 |
| LXSY-50FW | 50 | 280 | 116 | 207 | R2 | Flange connection according to GB/T17241.6-2008/XG1-2011 | 10 |
| D=φ165 D1=φ125 | |||||||
Note: The external dimensions and weight are for reference only, and the actual product shall prevail.
| Working Voltage | 3.6V | Protection level | IP68 |
| Electromagnetic environment level | E1 level, E2 level | Sensitivity level of upper and lower flow fields | U0D0 |
| Temperature Grade | T30 | Environmental Level | B-level, O-level |
| Maximum allowable pressure | 1.0MPa、1.6MPa | Electromechanical conversion method | Non magnetic or magneto resistive sensing |