LD69B series ABS corrosion-resistant solenoid valve
| Características del producto | Especificaciones técnicas | ||
| Suitable for medical machinery, chemical ingredient or piping systems, chemical reagent factories, chemical analysis instruments, sewage treatment equipment, scientific research instruments, environmental protection equipment, especially suitable for severe corrosion, high temperature and chemicals (including concentrated sulfuric acid and aqua regia). This series has multiple types, and you can choose according to your control needs. | Medium temperature: C1 0 ℃~60 ℃ C2 0 ℃~90 ℃ C3-10 ℃~150 ℃ | ||
| Work pressure: 0~1 bar, 0.1~6 bar | |||
| Operation mode: direct action pilot type | |||
| Tipo de funcionamiento: normalmente cerrado, normalmente abierto | |||
| Valve body material: ABS | |||
| Sealing material: standard FKM, other PTFE | |||
| Opciones de función | |||
| nombre en clave | Opciones de función | Descripción funcional | Parámetros eléctricos |
| NO | Tipo normalmente cerrado | Con la alimentación encendida, la válvula está abierta; con la alimentación apagada, la válvula está cerrada | Coil parameters: AC220V 380V DC24V 12V |
| K | Normalmente abierto | La válvula se cierra al encender el sistema y se abre al apagarlo. | Coil parameters: ordinary coil IP54, explosion-proof coil IP65 |
| E | Tipo a prueba de explosiones | Clase de protección contra explosiones: ExdII BT4 | Ordinary coil: AC 35W DC 24W |

| Specification parameter table (threaded connection) (The pressure needs to be customized for zero pressure starting, and the working pressure is related to the diameter size. It needs to be verified before ordering.) | |||||||
| Modelo | Interfaz G | Diámetro mm | Kv value | L | H/normally open type | Presión de trabajo (bar) | |
| Tipo de acción directa | Pilot | ||||||
| LD6915B | 1/2 | 15 | 4 | 98 | 117 | 0~1 | 0.1~6 |
| LD6920B | 3/4 | 20 | 6 | 103 | 137 | 0~1 | 0.1~6 |
| LD6925B | 1 | 25 | 9 | 120 | 151 | 0~1 | 0.1~6 |
| LD6932B | 11/4 | 32 | 13 | 130 | 207 | 0~1 | 0.1~6 |
| LD6940B | 11/2 | 40 | 18 | 145 | 215 | 0~1 | 0.1~6 |
| LD6950B | 2 | 50 | 30 | 180 | 232 | 0~1 | 0.1~6 |
| LD6965B | 21/2 | 65 | 45 | 215 | 260 | 0~1 | 0.1~6 |
| LD6980B | 3 | 80 | 70 | 255 | 290 | 0~1 | 0.1~6 |
| Specification parameter table (flange connection) (The pressure needs to be customized for zero pressure starting, and the working pressure is related to the diameter size. It needs to be verified before ordering.) | ||||||||||
| Modelo | Diámetro mm | Valor Cv | L | H/normally open type | D | D1 | b | n-d | Work pressure(bar) | |
| Tipo de acción directa | Pilot | |||||||||
| LD6915BF | 15 | 4 | 98 | 117 | 0~1 | 0.1~6 | ||||
| LD6920BF | 20 | 6 | 103 | 137 | 0~1 | 0.1~6 | ||||
| LD6925BF | 25 | 9 | 120 | 151 | 0~1 | 0.1~6 | ||||
| LD6932BF | 32 | 13 | 130 | 207 | 0~1 | 0.1~6 | ||||
| LD6940BF | 40 | 18 | 145 | 215 | 0~1 | 0.1~6 | ||||
| LD6950BF | 50 | 30 | 180 | 232 | 0~1 | 0.1~6 | ||||
| LD6965BF | 65 | 45 | 215 | 260 | 0~1 | 0.1~6 | ||||
| LD6980BF | 80 | 70 | 255 | 290 | 0~1 | 0.1~6 | ||||
sugerencias de optimización
*When designing control schemes, try to choose normally closed (NC) type. If the solenoid valve has a longer opening time and a shorter closing time, choose normally open (NO) type.
*El fluido contiene impurezas, por lo que se debe instalar un filtro de malla (con un tamaño de malla ≥ 60) delante de la válvula.
*La orientación de la marca del cuerpo de la válvula debe coincidir con la dirección del flujo del fluido.
*The working pressure of coils providing special voltage may vary, please be sure to consult our factory first
*Respetamos su confidencialidad y toda la información está protegida.
Soy Leo, el jefe del equipo de ventas de Huaxiang. Mi equipo y yo estaremos encantados de conocerle y saber todo sobre su negocio, requisitos y expectativas.
*Respetamos su confidencialidad y toda la información está protegida.
Soy Leo, el jefe del equipo de ventas de Huaxiang. Mi equipo y yo estaremos encantados de conocerle y saber todo sobre su negocio, requisitos y expectativas.