LD69B series ABS corrosion-resistant solenoid valve
| Caractéristiques du produit | Caractéristiques techniques | ||
| Suitable for medical machinery, chemical ingredient or piping systems, chemical reagent factories, chemical analysis instruments, sewage treatment equipment, scientific research instruments, environmental protection equipment, especially suitable for severe corrosion, high temperature and chemicals (including concentrated sulfuric acid and aqua regia). This series has multiple types, and you can choose according to your control needs. | Medium temperature: C1 0 ℃~60 ℃ C2 0 ℃~90 ℃ C3-10 ℃~150 ℃ | ||
| Work pressure: 0~1 bar, 0.1~6 bar | |||
| Operation mode: direct action pilot type | |||
| Type de fonctionnement : normalement fermé, normalement ouvert | |||
| Valve body material: ABS | |||
| Sealing material: standard FKM, other PTFE | |||
| Options de fonctionnement | |||
| nom de code | Options de fonctionnement | Description fonctionnelle | Paramètres électriques |
| NON | Type normalement fermé | La vanne est ouverte lorsque l'alimentation est activée, et fermée lorsque l'alimentation est coupée | Coil parameters: AC220V 380V DC24V 12V |
| K | Normalement ouvert | Vanne fermée sous tension, vanne ouverte hors tension | Coil parameters: ordinary coil IP54, explosion-proof coil IP65 |
| E | Modèle antidéflagrant | Indice de protection contre les explosions : ExdII BT4 | Ordinary coil: AC 35W DC 24W |

| Specification parameter table (threaded connection) (The pressure needs to be customized for zero pressure starting, and the working pressure is related to the diameter size. It needs to be verified before ordering.) | |||||||
| Modèle | Interface G | Diamètre mm | Kv value | L | H/normally open type | Pression de service (bar) | |
| Type à action directe | Pilot | ||||||
| LD6915B | 1/2 | 15 | 4 | 98 | 117 | 0~1 | 0.1~6 |
| LD6920B | 3/4 | 20 | 6 | 103 | 137 | 0~1 | 0.1~6 |
| LD6925B | 1 | 25 | 9 | 120 | 151 | 0~1 | 0.1~6 |
| LD6932B | 11/4 | 32 | 13 | 130 | 207 | 0~1 | 0.1~6 |
| LD6940B | 11/2 | 40 | 18 | 145 | 215 | 0~1 | 0.1~6 |
| LD6950B | 2 | 50 | 30 | 180 | 232 | 0~1 | 0.1~6 |
| LD6965B | 21/2 | 65 | 45 | 215 | 260 | 0~1 | 0.1~6 |
| LD6980B | 3 | 80 | 70 | 255 | 290 | 0~1 | 0.1~6 |
| Specification parameter table (flange connection) (The pressure needs to be customized for zero pressure starting, and the working pressure is related to the diameter size. It needs to be verified before ordering.) | ||||||||||
| Modèle | Diamètre mm | Valeur Cv | L | H/normally open type | D | D1 | b | n-d | Work pressure(bar) | |
| Type à action directe | Pilot | |||||||||
| LD6915BF | 15 | 4 | 98 | 117 | 0~1 | 0.1~6 | ||||
| LD6920BF | 20 | 6 | 103 | 137 | 0~1 | 0.1~6 | ||||
| LD6925BF | 25 | 9 | 120 | 151 | 0~1 | 0.1~6 | ||||
| LD6932BF | 32 | 13 | 130 | 207 | 0~1 | 0.1~6 | ||||
| LD6940BF | 40 | 18 | 145 | 215 | 0~1 | 0.1~6 | ||||
| LD6950BF | 50 | 30 | 180 | 232 | 0~1 | 0.1~6 | ||||
| LD6965BF | 65 | 45 | 215 | 260 | 0~1 | 0.1~6 | ||||
| LD6980BF | 80 | 70 | 255 | 290 | 0~1 | 0.1~6 | ||||
suggestions d'optimisation
*When designing control schemes, try to choose normally closed (NC) type. If the solenoid valve has a longer opening time and a shorter closing time, choose normally open (NO) type.
*Le fluide contient des impuretés ; il convient donc d'installer un tamis filtrant (d'une taille de maille ≥ 60) en amont de la vanne.
*Le sens indiqué sur le corps de la vanne doit correspondre au sens d'écoulement du fluide
*The working pressure of coils providing special voltage may vary, please be sure to consult our factory first
*Nous respectons votre confidentialité et toutes les informations sont protégées.
Je suis Leo, le chef de l'équipe des ventes de Huaxiang. Mon équipe et moi-même serions heureux de vous rencontrer et d'en savoir plus sur votre activité, vos besoins et vos attentes.
*Nous respectons votre confidentialité et toutes les informations sont protégées.
Je suis Leo, le chef de l'équipe des ventes de Huaxiang. Mon équipe et moi-même serions heureux de vous rencontrer et d'en savoir plus sur votre activité, vos besoins et vos attentes.